Definition of power measurements according to the standards
DIN 40110-2 and IEEE 1459

Info Letter No. 22

There is a wide range of electronic measuring devices for the digital measurement of power quantities available today. A comparison between the various producers shows, that different measurement results may occur, especially in the case of reactive power measurement with a distorted sinusoidal shape and/or three-phase networks with a clearly unbalanced load.

This can cause problems in the design and operation of installations up to overloads and failures. The power measurement in multi-wire circuits is defined in the standards DIN 40110-2 (Germany) and IEEE 1459 (International). These fundamentals serve the basis for power calculations in modern measuring instruments.

All devices of the A. Eberle product range use the calculation method according to DIN 40110-2. In the following, the basic definitions of active, apparent and reactive power are first described and then illustrated with examples of the individual types of reactive power. In this context, the differences between power measurement in the single-phase and multi-phase system as well as special features in the 4- or 3-wire network are discussed.

Power definitions

Active power is the only power that can be calculated directly from the instantaneous values of voltage (?) und current ?(?). The instantaneous power (?) for each sampling point ? is calculated as the product of voltage and current.

p(t) = u(t) * i(t)

By integration of instantaneous power (?) within the time interval ? = ?2 − ?1 the total energy ? is calculated. The time interval ? is freely selectable and e.g. can be set to a half net frequency period (for TRMS fault records) or 15 minutes (for energy measurement).

E = \int^{t_{2}}_{t_{1}}p(t) dt

If energy is transported from a source to a consumer (e.g. light bulb, motor) and absorbed there, it is referred to active energy. In case of energy storage at the consumer (e.g. in capacitors) and the later return transport to the source, the energy is called reactive energy.

Therefore, power is defined as energy transport per time from a source to a load. The part of the power that is returned to the source within the considered time interval is called reactive power ?, while the part of the power which is converted at the load into other forms of power (e.g.  thermal power, light, mechanical power) is called active power ?. This examination shows clearly that the calculated value for active and reactive power is not only dependent on the voltage and current curve, but also on the considered time interval ?.

Apparent power

Apparent power is often used for the design of electrical equipment and can be derived from the TRMS1 values of voltage and current in single-phase systems and therefore has no sign.

S = U_{trms}* I_{trms}

The collective apparent power ?Σ of a three-wire system is calculated from the values of collective voltage ?Σ and collective current ?Σ, which are defined in DIN 40110-2.

 The meaning of these variables is explained in more detail in the section “Reactive power in the three-phase system”.

S_{Σ} =U_{Σ}* I_{Σ}

Active power

As mentioned before, active power ? represents the part of the power that is transported to the load within the considered time interval ? = ?2 − ?1 and does not return to the source. The active power is defined as the mean value of instantaneous power (?) and has an algebraic sign, which indicates the direction of energy flow depending on the counting arrow system.

P = \frac{1}{t_{2}-t_{1}}  \int^{t_{2}}_{t_{1}}p(t) dt = \frac{E}{T}

In contrast to apparent power, active power represents a temporal mean value, which allows the collective active power ?Σ of a three-wire system to be calculated as the sum of the active powers of the individual phases

P_{Σ} =P_{1}+P_{2}+P_{3}

Reactive Power

The reactive power represents the part of the power that is transferred from the source to the load and back again within the considered interval ? and is generally derived from the relationship:

Q = \sqrt{S^{2}-P^{2}}

Reactive power represents a derived quantity from apparent and active power and is never calculated directly.

The total reactive power of an electrical energy system ?Σ consists of 5 different types of reactive power, which can be summarized by square addition:

Q_{Σ} =\sqrt{Q_{h1}^{2}+Q_{hn}^{2}+Q_{d}^{2}+Q_{m}^{2}+Q_{u}^{2}}

For the calculation of reactive power, a general distinction must be made between single-phase and three-phase systems.

Need more information?

Contact us!


Contact

News from the product group

News

General Knowledge

Voltage Monitoring

Find out everything you need to know about voltage monitoring in this article. What is voltage monitoring, why is voltage monitoring essential for both energy supply companies and industrial companies and how is it implemented in compliance with standards?

Read more

General Knowledge

What Is Load Profile Measurement/Power Measurement?

This article explains the definition and difference between load profile measurement (RLM), power measurement and measuring the standard load profile. These are important methods for accurately recording energy consumption in commercial, large industrial plant as well as in the public energy grid.

Read more

Training Video

»PQMobil« Training Video 4: Create and Configure PQ Reports With Software WinPQ mobil

This video explains everything about creating and configuring power quality reports with »WinPQ mobil«.

Read more

Webinar

»PQSys« Webinar: PQ-Monitoring & Feeder Current Measurement in Low-Voltage Grids

Webinar recording from 17.04.2024: »PQSys - PQ-Monitoring & Feeder Current Measurement in Low-Voltage Grids«.

Read more

Training Video

»PQMobil« Training Video 3: Usability & Functions of the PQ-Box App

This video gives you an introduction to the usability and functions of the »PQ-Box App« for our portable power quality analysers.

Read more

Training Video

»PQMobil« Training Video 2: Menu Navigation and Operation of the PQ-Box

In this short introductory video, we present to you how to navigate and operate our portable power quality analysers »PQ-Box 150«, »PQ-Box 200« & »PQ-Box 300« of the PQ-Box family.

Read more

Training Video

»PQMobil« Training Video 1: Getting Started with the PQ-Box

This video shows in detail how to connect the »PQ-Box« and record measurements. The »WinPQ mobil« software is then used to visualize and analyse the measurement data and create a report.

Read more

General Knowledge

Residual current

In this article, you will learn about residual current measurement & residual current monitoring and why it is important to measure residual current.

Read more

General Knowledge

Power Quality

Good power quality is characterized by the fact that the mains voltage actually arriving at the consumer matches the mains voltage promised by the utility company.

Read more

General Knowledge

Reactive power – definition, calculation and measurement

The key role of reactive power in electrical engineering: definition, calculation, measurement and the differences to active power and apparent power. Find out how reactive power influences the efficiency of electricity grids and shapes energy transmission.

Read more

General Knowledge

What is apparent power and how is it calculated?

This article addresses the question of what apparent power is and how to calculate it. An understanding of apparent power is crucial for the correct dimensioning of inverters and therefore for the optimum efficiency and performance of photovoltaic systems.

Read more

General Knowledge

Ready for the smart grid of the future?

All information about smart grids/intelligent power grids, the technology behind them, advantages, disadvantages, challenges and current distribution.

Read more

Info letter

Information Letter No. 24: Integration guide for the metering of a power plant according to the Requirements for Generators (2016/631) RfG

Integration guide for the measurement of a power plant (EZA) according to VDE-AR 4110 and VDE-AR 4120.

Read more

Info letter

Info Letter No. 23: Direction of harmonics Sources of harmonics in the power system

Le sens du flux de puissance des harmoniques est déterminé par le signe de la puissance activ

Read more

Info letter

Info Letter No. 20: Capacitance of conductors

In the conductors of electrical power supplies, a distinction is made between the operating capacitance...

Read more

Info letter

Info Letter No. 19: The evaluation of power quality and detection of interference in medium voltage network

For various reasons, interest in the continuous monitoring of network quality in medium-voltage...

Read more

Info letter

Info Letter No. 8: Apparent power and reactive power in three-phase networks

The range of electromechanical and electronic measuring devices in analog - and digital technology...

Read more

Info letter

Info Letter No. 5: Zero sequence voltage in three-phase networks

With balanced network operation and inequality of the impedances in the consumer circuit, the phase...

Read more

Info letter

Info Letter No. 4: Summation of Alternating Currents

For the parallel connection of power sources, the principle of superposition applies, when all resources...

Read more

Info letter

Info Letter No. 2: Measurement Transformers in three-phase networks (Part 2)

In a symmetrically loaded three-wire three-phase network, a two-pole insulated voltage transformer...

Read more

Info letter

Info Letter No. 1: Measurement Transformers in three-phase networks (Part 1)

The direct connection of measuring devices into the network is limited for safety reasons to values...

Read more

Special Publication

Ferrari´s Meter vs. Electronic Meter

This technical report analyzes a power measurement at a large industrial customer. The customer records very high currents and fifth harmonic voltages during production time, which leads to poor voltage quality.

Read more

Special Publication

Angle determination of voltage and current harmonics in practice

Today's devices and equipment such as switched-mode power supplies, frequency converters, regulated drives, charging devices for e-mobiles or LED lighting work internally with high clock frequencies in order to regulate power efficiently. These can lead to both conducted and field-bound (coupled) influences in the energy grid. In this technical report, we explain how you can detect these sources of interference in the grid using suitable measuring technology.

Read more

General Knowledge

All „Supra“ with your grid?

Today's devices and equipment such as switched-mode power supplies, frequency converters, controlled drives, charging devices for e-mobiles or LED lighting work internally with high clock frequencies in order to regulate power efficiently. These can lead to line-borne as well as field-borne (coupled) interference in the power grid. In this technical report, we explain how you can detect these sources of interference in the grid using suitable measurement technology.

Read more

General Knowledge

Power Quality Analysis: Tips and Tricks II

Useful tips & tricks for handling Power Quality measuring devices and typical user errors - now in our two-part article! This article provides further insights and practical tips and application examples for power quality analysis.

Read more

Contact request:



* Mandatory

Your data is being processed

a-eberle kontakt newsletter ×

Our seminars &
webinars

► Register here!

x