DC frequency analysis to 170 kHz

PQ-Box 300

This mobile power quality network analyzer, power meter and transient recorder allows permanent DC frequency analysis to 170 kHz. The Class A device has been developed for measurements on low, medium and high-voltage networks and is ideally designed for measurements in harsh environments or where space is very limited. In addition, the device allows the power quality of public and industrial networks to be assessed. The device is thus an essential aid for analysis in high-frequency ranges.

Further questions or want to start an enquiry? Please click “Product Enquiry”.

Cross-product downloads

Accessories

Catalogue
Current Clamp
Rogowski Current Clamps
Adapter Cable Set
Calib-Box
External Power Supply
Bags
Navilog GPS Clock
NIS-Clock
Istolation Cover
Sensors

Permanent recording of frequencies up to 170 kHz

Computation from 8 kHz to 170 kHz takes place using a continuous FFT at 200 msec intervals. More than 5000 different measured values can be recorded permanently with measuring intervals from 200ms. In addition, ½ periods (10 ms) minimum and maximum values are recorded.

network-analyzer
network-analyzer

WLAN interface for cableless communication with the software & app

In addition to a USB and ethernet interface, the data recorded by the PQ-Box 300 can be transferred to the evaluation PC via a fast WLAN interface. The network analyzercomes with the extensive WinPQ mobile evaluation software, which can be installed on as many PCs as you wish. To round off the excellent user experience, we have developed the PQ-Box app for both Android and iOS. The app allows you to display a wide range of online measurements and alter configurations for current and voltage transformers, measurement intervals or nominal voltages of the PQ-Box 300.

All the standards and protocols upheld – making our products fit for the future

The network analyzer PQ-Box 300 creates an automatic standard assessment and event record to:

  • EN 50160
  • IEC 61000-2-2
  • IEC 61000-2-12
  • IEC 61000-2-4 (Class 1; 2; 3)
  • NRS 048
  • IEEE 519
  • VDE N-4105
  • IEC 61000-4-30 Ed. 3 Class A
  • IEC 61000-4-7
  • IEC 61000-4-15
  • IEC 62586-2 Ed. 2
  • IEC 62586-1
network-analysis-device

Simple menu navigation and intuitive operation of the measuring device

When designing the menu navigation of our mobile network analyzers, we focused on enabling particularly user-friendly and intuitive navigation and thus operation of the measuring device. This means that you as a user can quickly find your way around the device when using the PQ-Box and concentrate on the essentials: the measurement. The user interface of the PQ-Box 150 is identical to that of the PQ-Box 200 and PQ-Box 300 models – also from the PQ-Box family from “A. Eberle”.

Standard accessories & device installation – how your PQ Box arrives

  • PQ mains analyser »PQ-Box 300«
  • USB cable
  • 4mm safety sockets incl. inserts for worldwide sockets
  • 5 Delphin terminals (3x red, 1 x green, 1 x blue)
  • Case for measuring device and accessories
  • Hardware operating instructions (software instructions via website and included in software)
  • QR code for downloading WinPQ mobile software
  • TCP-IP connection cable
  • Wide-range AC/DC power supply unit for supply via test leads
  • Two black stacking plugs (stacking of measuring cable and power supply on one terminal)
  • Carrying and fastening strap
  • Free connection set for AUX input (4mm safety plug)

Ripple control signal analysis

In addition to measuring the ripple control level, the network analyzer is able to trigger a ripple control frequency and capture the voltages and currents for a set frequency. The complete telegram can be shown to a length of 210 seconds, while a wide range of parameters can be set in the network analysis device (triggering threshold, recording threshold, ripple control frequency, bandwidth of the filter curve for ripple control frequency).

You have questions
about the PQ-Box 300?

Our specialists will be happy to help you!


Contact us

News from the Productgroup

PQMobil – News

General Knowledge

Voltage Monitoring

1. July 2024

Find out everything you need to know about voltage monitoring in this article. What is voltage monitoring, why is voltage monitoring essential for both energy supply companies and industrial companies[…]

Read more

General Knowledge

What Is Load Profile Measurement/Power Measurement?

25. June 2024

This article explains the definition and difference between load profile measurement (RLM), power measurement and measuring the standard load profile. These are important methods for accurately recording[…]

Read more

Special Publication

Ferrari´s Meter vs. Electronic Meter

9. April 2024

This technical report analyzes a power measurement at a large industrial customer. The customer records very high currents and fifth harmonic voltages during production time, which leads to poor voltage[…]

Read more

General Knowledge

Residual current

6. March 2024

In this article, you will learn about residual current measurement & residual current monitoring and why it is important to measure residual current.[…]

Read more

General Knowledge

Power Quality

6. March 2024

Good power quality is characterized by the fact that the mains voltage actually arriving at the consumer matches the mains voltage promised by the utility company.[…]

Read more

General Knowledge

Reactive power – definition, calculation and measurement

6. March 2024

The key role of reactive power in electrical engineering: definition, calculation, measurement and the differences to active power and apparent power. Find out how reactive power influences the efficiency[…]

Read more

General Knowledge

What is apparent power and how is it calculated?

6. March 2024

This article addresses the question of what apparent power is and how to calculate it. An understanding of apparent power is crucial for the correct dimensioning of inverters and therefore for the optimum[…]

Read more

Special Publication

Angle determination of voltage and current harmonics in practice

24. August 2023

Today’s devices and equipment such as switched-mode power supplies, frequency converters, regulated drives, charging devices for e-mobiles or LED lighting work internally with high clock frequencies in[…]

Read more

General Knowledge

All „Supra“ with your grid?

23. May 2023

Today’s devices and equipment such as switched-mode power supplies, frequency converters, controlled drives, charging devices for e-mobiles or LED lighting work internally with high clock frequencies in[…]

Read more

General Knowledge

Power Quality Analysis: Tips and Tricks II

28. April 2023

Useful tips & tricks for handling Power Quality measuring devices and typical user errors – now in our two-part article! This article provides further insights and practical tips and application examples[…]

Read more

General Knowledge

Power Quality Analysis: Tips and Tricks I

27. April 2023

Useful tips & tricks for handling Power Quality measuring devices and typical user errors – now in our two-part article! This article explains tips and tricks for performing power quality measurements.[…]

Read more

General Knowledge

Four ways to measure current

26. April 2023

The following technical report examines various methods for measuring current. It discusses how currents are measured using power analyzers and current clamps. The respective advantages and disadvantages[…]

Read more

General Knowledge

Cos ϕ vs. power factor λ – Practice

25. April 2023

This second technical report on the subject of reactive power and in particular the distortion reactive power supplements the first contribution “Cos ϕ vs. power factor λ – Theory”. In this article,[…]

Read more

General Knowledge

Cos ϕ vs. power factor λ – Theory

24. April 2023

This technical report discusses the distinction between power factor and cosine phi. Cosine Phi, formerly widely known as the ratio of active power to apparent power, however, has a different meaning for[…]

Read more

Special Publication

Mains feedback interferes with protective devices

10. October 2022

In a photography and design studio, located in a large industrial park, a RCD tripped frequently. Due to the permanent power cuts, the employees of the studio could not work properly. This article shows[…]

Read more

Special Publication

Creating Power Quality surveys with PQ-Box and WinPQ mobil software

18. May 2022

The following report displays the PQ-Box and WinPQ mobil software interact to allow an evaluation of the disturbance levels at a measuring point according to approved grid norms.[…]

Read more

Special Publication

Measurement of voltage distortions in industrial grids with the PQ-Box 50

14. April 2022

It is important to find disturbances in the system in a fast and reliable way. This report shows an example for trouble shooting with the Power Quality analyzer PQ-Box 50. […]

Read more

Product innovation

Product discontinuation until 30.06.2021: PQ-Box 100 & PQ-Box 100 DIN Rail mounted

12. April 2022

Power Quality analyzer PQ-box 100 – discontiuation from mid of 2021.[…]

Read more

Special Publication

Power Quality Measurements: The Third Harmonic

16. February 2022

This special publication intends to illustrate a typical power quality measurement and the aspects, which should be taken into consideration conducting the measurements. […]

Read more

General Knowledge

Power Quality Measurements: The N-Conductor & Harmonics

2. February 2022

In power quality measurements, odd harmonics such as the 15th, 21st & 27th are often violated. What are harmonics anyway, how does this circumstance occur and what influence does this have on the neutral[…]

Read more

Contact request:



* Mandatory

Your data is being processed

a-eberle kontakt newsletter ×