»EORSys« Webinar

Short-Circuit & Earth Fault Detection in Digital & Analog Substations

Webinar Recording

Title: Short-Circuit & Earth Fault Detection in Digital & Analog Substations with »EORSys«

Date: 07.05.2024

Description:
On May 7th, Gerald Jacob, product manager of »EORSys« – hosted an online webinar on short-circuit and earth fault indication in digital & analogue secondary substations. In this presentation, Gerald delved into the functional differences between our combined short-circuit & earth fault indicators EOR-1DS & EOR-3DS, outlined existing competitive advantages (benefits), and presented specific application examples.

Content:
• Increasing demands on secondary substations in times of transformation in the low-voltage grid and staff shortage
• Remotely reported and remotely controlled secondary substations as a core component of the smart grid of tomorrow
• Introduction of fault indicators EOR-1DS & EOR-3DS
EOR-3DS as a digitalization unit for secondary substations
• Application example from a major German DSO

Click here to watch the webinar recording:

Do you have any questions about »EORSys«?

Contact us here!


Get in touch now

News from the product group

EORSys - News

General Knowledge

The Future of the Distribution Grid: Focus on Digital Secondary Substations

In this technical report, Gerald Jacob (Product Manager »EORSys«) uses a specific example to illustrate how distribution system operators can meet the challenges of energy transition in the medium and low-voltage grid with future-proof secondary substations.

Read more

General Knowledge

Earth fault explained – basics and functions of an electrical phenomenon

Everything you need to know about earth faults - from the basics, causes and examples to the consequences. Find out more in this article about earth fault clearing, compensation, location and the benefits of constant monitoring to ensure a safe power grid.

Read more

General Knowledge

Ready for the smart grid of the future?

All information about smart grids/intelligent power grids, the technology behind them, advantages, disadvantages, challenges and current distribution.

Read more

Info letter

Info Letter No. 21: The influence of the contact resistance at the earth-fault location on the zero sequence voltage UEN in compensated networks

The earth fault in compensated networks is usually presented without a contact resistance at the fault...

Read more

Info letter

Info Letter No. 20: Capacitance of conductors

In the conductors of electrical power supplies, a distinction is made between the operating capacitance...

Read more

Info letter

Info Letter No. 18: Transient relay for high resistance, intermittent and recurrent earth faults (Part 2)

Figure 3 can also be used for the determination of static earth faults. In an isolated network the entire...

Read more

Info letter

Info Letter No. 17: Transient relay for high resistance, intermittent and recurrent earth faults (Part 1)

The statistics show that earth faults constitute a large proportion of network faults. Conventional relays...

Read more

Info letter

Info Letter No. 15: Earth fault location using the harmonic procedure (Part 2)

For the study of the behaviour of the harmonic currents and voltages in the compensated network, at...

Read more

Info letter

Info Letter No. 14: Earth fault location using the harmonic procedure (Part 1)

For the following considerations a network with three outputs and an earth fault in line 1 in output...

Read more

Info letter

Info Letter No. 12: E-coil control: Resonance curve procedure – Location curve procedure

In "compensated networks" the current through the point of failure is minimised with the help of an...

Read more

Info letter

Info Letter No. 6: Detection of transient earth faults

When there is an earth fault in a conductor, at the start of the earth fault three events occur at the...

Read more

Info letter

Info Letter No. 4: Summation of Alternating Currents

For the parallel connection of power sources, the principle of superposition applies, when all resources...

Read more

Info letter

Info Letter No. 3: The E-coil in general

The earth fault compensation coil, e-coil or also called the Petersen coil after its inventor, is connected...

Read more

Special Publication

Cost Efficient Management of Digital Secondary Substations: Earth Fault Indicator EOR-3DS as Digitisation Unit for Secondary Substations

Digital secondary substations are becoming a key element for distribution system operators in terms of automation, monitoring, and efficient operations of their networks. Read this technical report about the EOR-3DS in its role as digitisation unit for secondary substations.

Read more

Contact request:



* Mandatory

Your data is being processed

a-eberle kontakt newsletter ×

Our seminars &
webinars

► Register here!

x