We offer power quality analysis with troubleshooting in accordance with EN 50160 and IEC 61000 for electrical utilitites and industrial companies as a service. As an internationally recognised manufacturer in the field of premium portable power quality analysers, we can draw on a wide range of power network analysers with the appropriate accessories for your measurement projects. The analysis results are being documented in a detailed and problem-related report. We then discuss and develop possible solutions together with you, based on the measured data.

Further questions or want to start an enquiry? Please click “Service Enquiry”.

FAQ on Power Quality analysis

What is a grid analysis?

Grid analysis (also network analysis, power network analysis or mains analysis) as an umbrella term refers to a specialised process that aims to examine the structure, performance and reliability of power supply grids. These analyses are carried out to ensure the optimal distribution of energy, identify bottlenecks, improve the efficiency of energy transmission and ensure the stability of the grid under different load conditions. Grid analyses in this context typically include the evaluation of network/grid topologies, the simulation of load flow, the analysis of short-circuit currents, the investigation of voltage stability and the evaluation of grid response to renewable energy sources.

In the context of energy supply and grid operation, grid analyses are also more specifically understood to mean the measurement and analysis of energy networks (public or commercial/industrial) using suitable measurement technology to determine voltage quality/power quality in order to ensure the security of supply of electrical transmission and distribution grids.

When/why is a grid analysis necessary?

What are the requirements for a grid analysis?

How does a grid analysis work?

Which parameters are recorded during a grid analysis?

Grid analysis according to DIN EN 50160

Devices for grid analysis

Discover the causes of grid problems quickly and in a targeted way

With our innovative products and methods, we are able to identify and locate the causes of faults in the energy grid quickly and easily. Whether in low, medium or high-voltage grids – we will find what is wrong. Quality of supply is playing an ever greater role today, now that the energy transition is under way. Accordingly, it is not only important to eliminate faults as quickly as possible, but also to work preventively against potentially costly damages and production breakdowns.

Our experts’ extensive experience in the sector

Our specialised team of experts has over 25 years of experience in the sector. During this time, they have built up a wealth of experience. In keeping with this, our experts have been certified as “Power Quality Experts” (VDE). This means they know the forces in play and how to overcome the difficulties our customers are in. Training is a top priority with us. Our experts not only build on their own know-how, but also cooperate on research projects with universities, generating new knowledge.

Use of our high-grade Power Quality Analyzers

Even the greatest expert cannot achieve the desired result without the right tools. Consequently, as a market leader for mobile power quality devices, we work exclusively with modern, innovative analyzers that are equipped for every application. Our devices are certified to Class A, the highest measurement standard. This means they are fully equipped to deliver the extensive, detailed measurement data needed for a well-founded analysis.

Problem-focused assessment for every application

In many fields of life, we are becoming ever more dependent on high-quality power supplies. That is why the following applies to our services: no matter whether in industrial environments or for energy suppliers – through the right combination of expert knowledge and measurement devices, we can create a solution to fit any problem. Our experts are also happy to take on the role of independent consultant for the implementation of such solutions.

References

Practical examples from customer projects

Customer: Waste-to-Energy Plant

Application

The waste delivered by the refuse trucks is dumped into a bunker. Two gantry cranes with refuse grabs mix the refuse and fill three kiln lines with it. Both cranes and their equipment were replaced.

Challenge

Since then, there has been an increased failure of components in other parts of the plant that are connected to the same transformer. The feed of the main-distribution was monitored over a week with a PQ-Box 300.

  • The power quality according to IEC 61000-2-4 (limits up to 9 kHz) could be complied with, but
  • supraharmonics around 30 kHz were massively above the limit values of the IEC 61000-2-2 and
  • the oscilloscope showed a big noise on the sinewave.

Solution

A further EMC analysis revealed glaring deficiencies in the shielding and earthing of the cables between the inverters in the machine cabinet and the motors on the crane systems. The crane manufacturer suggested using an isolating transformer to decouple the system from the rest of the low-voltage supply.


Customer: Printing Plate Manufacturer

Application

High-purity aluminum (99.9%) is required for the production of aluminum printing plates. This is supplied on rolls several kilometers long. The aluminum is electrochemically roughened and anodized and then coated with a light-sensitive layer. Finally, the printing plates are cut from the coil into pieces and packaged.

Challenge

In one machine segment, there were frequent failures of VFDs and power supply units. The feed of the sub-distribution was monitored over a week with a PQ-Box 300. The following observations were made:

  • The power quality according to IEC 61000-2-4 could not be complied with,
  • higher frequency harmonics were massively above their limit values,
  • the oscilloscope showed marked commutation notches and
  • commutation notches led to steep-flanked current characteristics, which damaged the loads over time.

Solution

The disturbance was related to the powerful thyristor-controlled rectifier, which was operated on the same transformer. To dampen the commutation dips, a line choke upstream of the rectifier in combination with a passive high-frequency filter was recommended.

Would you like support with your grid analysis?

Our experts will be happy to help you!


Contact

News from the Productgroup

PQMobil – News

General Knowledge

Voltage Monitoring

1. July 2024

Find out everything you need to know about voltage monitoring in this article. What is voltage monitoring, why is voltage monitoring essential for both energy supply companies and industrial companies[…]

Read more

General Knowledge

What Is Load Profile Measurement/Power Measurement?

25. June 2024

This article explains the definition and difference between load profile measurement (RLM), power measurement and measuring the standard load profile. These are important methods for accurately recording[…]

Read more

Special Publication

Ferrari´s Meter vs. Electronic Meter

9. April 2024

This technical report analyzes a power measurement at a large industrial customer. The customer records very high currents and fifth harmonic voltages during production time, which leads to poor voltage[…]

Read more

General Knowledge

Residual current

6. March 2024

In this article, you will learn about residual current measurement & residual current monitoring and why it is important to measure residual current.[…]

Read more

General Knowledge

Power Quality

6. March 2024

Good power quality is characterized by the fact that the mains voltage actually arriving at the consumer matches the mains voltage promised by the utility company.[…]

Read more

General Knowledge

Reactive power – definition, calculation and measurement

6. March 2024

The key role of reactive power in electrical engineering: definition, calculation, measurement and the differences to active power and apparent power. Find out how reactive power influences the efficiency[…]

Read more

General Knowledge

What is apparent power and how is it calculated?

6. March 2024

This article addresses the question of what apparent power is and how to calculate it. An understanding of apparent power is crucial for the correct dimensioning of inverters and therefore for the optimum[…]

Read more

General Knowledge

Ready for the smart grid of the future?

6. March 2024

All information about smart grids/intelligent power grids, the technology behind them, advantages, disadvantages, challenges and current distribution.[…]

Read more

Product innovation

Product announcement: »I-Sense« for feeder current measurement in future-proof secondary substations available as of 15/09/2023

16. October 2023

»I-Sense« Feeder Current Measurement for up to 16 feeders. Available to order now.[…]

Read more

Special Publication

Angle determination of voltage and current harmonics in practice

24. August 2023

Today’s devices and equipment such as switched-mode power supplies, frequency converters, regulated drives, charging devices for e-mobiles or LED lighting work internally with high clock frequencies in[…]

Read more

Product innovation

Product discontinuation: Power Quality Analyser PQI-DA, as of 09.08.2023

9. August 2023

Power Quality Analyser PQI-DA is currently scheduled for product discontinuation.[…]

Read more

General Knowledge

All „Supra“ with your grid?

23. May 2023

Today’s devices and equipment such as switched-mode power supplies, frequency converters, controlled drives, charging devices for e-mobiles or LED lighting work internally with high clock frequencies in[…]

Read more

General Knowledge

Power Quality Analysis: Tips and Tricks II

28. April 2023

Useful tips & tricks for handling Power Quality measuring devices and typical user errors – now in our two-part article! This article provides further insights and practical tips and application examples[…]

Read more

General Knowledge

Power Quality Analysis: Tips and Tricks I

27. April 2023

Useful tips & tricks for handling Power Quality measuring devices and typical user errors – now in our two-part article! This article explains tips and tricks for performing power quality measurements.[…]

Read more

General Knowledge

Four ways to measure current

26. April 2023

The following technical report examines various methods for measuring current. It discusses how currents are measured using power analyzers and current clamps. The respective advantages and disadvantages[…]

Read more

General Knowledge

Cos ϕ vs. power factor λ – Practice

25. April 2023

This second technical report on the subject of reactive power and in particular the distortion reactive power supplements the first contribution “Cos ϕ vs. power factor λ – Theory”. In this article,[…]

Read more

General Knowledge

Cos ϕ vs. power factor λ – Theory

24. April 2023

This technical report discusses the distinction between power factor and cosine phi. Cosine Phi, formerly widely known as the ratio of active power to apparent power, however, has a different meaning for[…]

Read more

Special Publication

Innovative & economical “system solutions” in the age of energy grid transformation

2. February 2023

The transformation of the energy industry from a centralized structure to a decentralized energy supply is creating complex energy networks with volatile load flows and changing load flow directions. Grid[…]

Read more

Special Publication

Mains feedback interferes with protective devices

10. October 2022

In a photography and design studio, located in a large industrial park, a RCD tripped frequently. Due to the permanent power cuts, the employees of the studio could not work properly. This article shows[…]

Read more

Blogpost

DAKKS Calibration Report: PQI-DE & PQI-DA Smart With Sensational Results

11. August 2022

In the DAKKS calibration according to VDE-AR 4110 Annex F, our power quality analyzers PQI-DE & PQI-DA smart have achieved sensational accuracy values.[…]