WinPQ

Monitor Power Quality

störschreiber-gerät
Top-down analysis processes
spannung-messtechnik-a-eberle
An extremely wide range of power quality reports and statistics
Simulation-Messwerte-Prozesswerte
Autoreporting, by which faults are automatically sent to the database
com-server-tbox-server
A separate process plan for every measurement point
störschreiber-gerät
Top-down analysis processes
spannung-messtechnik-a-eberle
An extremely wide range of power quality reports and statistics
Simulation-Messwerte-Prozesswerte
Autoreporting, by which faults are automatically sent to the database
com-server-tbox-server
A separate process plan for every measurement point

A unique combination: Power Quality System with the WinPQ visualisation software

The system solution for power quality monitoring, with built-in fault log and energy measurements for high, medium and low-voltage networks

The client-server software with WinPQ database is an intelligent system solution for the fully automated parallel monitoring of all faults and network quality via numerous measurement devices. Various different device variants are available for the most diverse requirements and voltage levels. The evaluation software supports all built-in fault event logs from A. Eberle. Communication with the devices can take place via TCP/IP, LWL connection, RS232, 3G, 4G and analogue modem. In addition, all measurement data form the mobile network analyzers can be imported into the database, in order to correlate it with the data from the built-in devices.

The database is as a rule installed on a server in order to ensure permanent operation. As many WinPQ client installations as desired can work with the database in parallel.

The most important features of the system include:

  • Simultaneous, parallel reading of all devices. This guarantees a rapid reaction time from the system
  • Automatic reporting for fault events and automatic creation of power quality reports, including for the control room
  • User-friendly software providing a clear overview of many devices and large data quantities

WinPQ can be used with the following databases: PostgreeSQL, MySQL, Maria DB and MS SQL.

The principle: top-down analysis

With the WinPQ database analysis software, you are only ever a mouse click away from abstract representations of numerous time-independent measured values: from charts showing levels over time to highly accurate fault logs.

WebPQTM Visualizer

The intelligent add-on to WinPQ

The fully responsive & web-based user interface as an installable app for the evaluation of your Power Quality data in your local IT environment!

Challenges in the supply networks

Electrical supply grids are currently subject to profound change processes. Active power electronics, as found in switching power supplies and inverters, is omnipresent. To achieve CO2 reductions, small, renewable energy generators are being built everywhere. Large, conventional power plants are disappearing. Phenomena such as load flow reversals, overloads, voltage band increases at entry points and asymmetries are now part of daily business. This can be a problem, for example, for highly optimised EDP facilities, but also for industrial control systems that are sensitive to short-term supply failures, harmonics and transient events. The stability of the network may even be in question.

Document power quality continuously using large data quantities

It was only in 2014 that the German Supreme Court determined that electricity is subject to the Product Liability Act. Thus: distribution grid operators are liable for damages caused by poor power quality. With the combination of the Class A-certified measurement device family PQSys and the fully automated server solution WinPQ, A. Eberle offers a comprehensive system for watertight records of power quality. It makes users able to document, assess and demonstrate power quality continuously at any time. Faults can be recognised early on, their causes determined and eliminated. All built-in fault logs and mobile network analyzers from A. Eberle are supported by a SQL database server, to which they can be connected across networks and even in great numbers. Communications connection via control protocols such as IEC 61850, Ethernet, 3G, 4G and analogue modems. The most important thing: the WinPQ software is on top form where large data quantities need to be handled. Automated reporting assistants will fully automatically comb the data for you and report only the most important facts. You can receive standard reports and alarms by email if you desire, or have them laid down in standard formats such as Comtrade, PQDiff or PDF in network drives. Further action is not required. With our well-tuned system solution, consisting of hardware and software, you can keep an eye on power quality at any time.

Our WinPQ system solution

The WinPQ system solution for all built-in A. Eberle fault recorders, power quality monitoring devices and mobile network analyzers. Monitor power quality permanently – from the high-voltage grid to the end user in a system. Intuitive operation despite the vast amount of data handled.

Uses of the software:

  • Fully automatic network monitoring
  • Visualisation
  • Database management
  • Data evaluation
  • Device and client administration

You can find more information and a detailed list of software functions in our flyer.
Find out more.

News from the Productgroup

Power Quality – News

General Knowledge

Voltage Monitoring

1. July 2024

Find out everything you need to know about voltage monitoring in this article. What is voltage monitoring, why is voltage monitoring essential for both energy supply companies and industrial companies[…]

Read more

General Knowledge

What Is Load Profile Measurement/Power Measurement?

25. June 2024

This article explains the definition and difference between load profile measurement (RLM), power measurement and measuring the standard load profile. These are important methods for accurately recording[…]

Read more

Special Publication

Ferrari´s Meter vs. Electronic Meter

9. April 2024

This technical report analyzes a power measurement at a large industrial customer. The customer records very high currents and fifth harmonic voltages during production time, which leads to poor voltage[…]

Read more

General Knowledge

Residual current

6. March 2024

In this article, you will learn about residual current measurement & residual current monitoring and why it is important to measure residual current.[…]

Read more

General Knowledge

Power Quality

6. March 2024

Good power quality is characterized by the fact that the mains voltage actually arriving at the consumer matches the mains voltage promised by the utility company.[…]

Read more

General Knowledge

Reactive power – definition, calculation and measurement

6. March 2024

The key role of reactive power in electrical engineering: definition, calculation, measurement and the differences to active power and apparent power. Find out how reactive power influences the efficiency[…]

Read more

General Knowledge

What is apparent power and how is it calculated?

6. March 2024

This article addresses the question of what apparent power is and how to calculate it. An understanding of apparent power is crucial for the correct dimensioning of inverters and therefore for the optimum[…]

Read more

General Knowledge

Ready for the smart grid of the future?

6. March 2024

All information about smart grids/intelligent power grids, the technology behind them, advantages, disadvantages, challenges and current distribution.[…]

Read more

Product innovation

Product announcement: »I-Sense« for feeder current measurement in future-proof secondary substations available as of 15/09/2023

16. October 2023

»I-Sense« Feeder Current Measurement for up to 16 feeders. Available to order now.[…]

Read more

Special Publication

Angle determination of voltage and current harmonics in practice

24. August 2023

Today’s devices and equipment such as switched-mode power supplies, frequency converters, regulated drives, charging devices for e-mobiles or LED lighting work internally with high clock frequencies in[…]

Read more

Product innovation

Product discontinuation: Power Quality Analyser PQI-DA, as of 09.08.2023

9. August 2023

Power Quality Analyser PQI-DA is currently scheduled for product discontinuation.[…]

Read more

General Knowledge

All „Supra“ with your grid?

23. May 2023

Today’s devices and equipment such as switched-mode power supplies, frequency converters, controlled drives, charging devices for e-mobiles or LED lighting work internally with high clock frequencies in[…]

Read more

General Knowledge

Power Quality Analysis: Tips and Tricks II

28. April 2023

Useful tips & tricks for handling Power Quality measuring devices and typical user errors – now in our two-part article! This article provides further insights and practical tips and application examples[…]

Read more

General Knowledge

Power Quality Analysis: Tips and Tricks I

27. April 2023

Useful tips & tricks for handling Power Quality measuring devices and typical user errors – now in our two-part article! This article explains tips and tricks for performing power quality measurements.[…]

Read more

General Knowledge

Four ways to measure current

26. April 2023

The following technical report examines various methods for measuring current. It discusses how currents are measured using power analyzers and current clamps. The respective advantages and disadvantages[…]

Read more

General Knowledge

Cos ϕ vs. power factor λ – Practice

25. April 2023

This second technical report on the subject of reactive power and in particular the distortion reactive power supplements the first contribution “Cos ϕ vs. power factor λ – Theory”. In this article,[…]

Read more

General Knowledge

Cos ϕ vs. power factor λ – Theory

24. April 2023

This technical report discusses the distinction between power factor and cosine phi. Cosine Phi, formerly widely known as the ratio of active power to apparent power, however, has a different meaning for[…]

Read more

Special Publication

Innovative & economical “system solutions” in the age of energy grid transformation

2. February 2023

The transformation of the energy industry from a centralized structure to a decentralized energy supply is creating complex energy networks with volatile load flows and changing load flow directions. Grid[…]

Read more

Special Publication

Mains feedback interferes with protective devices

10. October 2022

In a photography and design studio, located in a large industrial park, a RCD tripped frequently. Due to the permanent power cuts, the employees of the studio could not work properly. This article shows[…]

Read more

Blogpost

DAKKS Calibration Report: PQI-DE & PQI-DA Smart With Sensational Results

11. August 2022

In the DAKKS calibration according to VDE-AR 4110 Annex F, our power quality analyzers PQI-DE & PQI-DA smart have achieved sensational accuracy values.[…]

Read more