leittechnik-fernwirkprotokoll

Transformer monitor and voltage regulator

REG-D®

The REG-D® voltage regulator allows both very simple and highly complex measurement, control and regulation tasks for tapped transformers. The REG-D® can also be used as a transformer monitor as per IEC 60354 or IEC 60076, as a transducer, recorder, statistical unit and ParaGramer.

Further questions or want to start an enquiry? Please click “Product Enquiry”.

Cross-product downloads

Special Publications
Calculating Tools
Product overview A. Eberle

REG-D

Instruction Manual
Product and Safety Instructions
Virtual Instruction Manual
Instruction Manual TMM
Technical Data Sheets
Firmware
Short Instruction Manual
Test Template
REGUpdate

Unique Flexibility

Through our many years of experience in the industry, we know that every customer and every project has specific requirements. Accordingly, we have developed the transformer monitor REG-D® in such a way that it can respond very flexibly to these requirements, which is unique in this form. For example, the REG-D® offers a flexibly expandable number of inputs and outputs, a wide range of applications through software features, and free programmability.

transformer-monitor
transformer-monitor

19″ plug technology as a tried-and-tested model

The design of the transformer monitor REG-D® allows the installation in 19″ subracks, wall-mounted and panel-mounted housings. Easy and simple replacement of the devices, customized housings as well as wiring are made possible by the 19” plug-in technology of the REG-D®. In addition, the configuration possibilities are inexhaustible, together with other products from A. Eberle, but also with devices from other manufacturers.

The right control protocol for every application

The communication interfaces of the transformer monitor REGSys® have the possibility of role-based user administration (RBAC) incl. authentication via RADIUS.
REGSys® can communicate with a central control system via various protocols.
The following protocols are available:

  • IEC 60870-5-101/103/104
  • IEC 61850 (Server, Client, GOOSE, 9-2 Sampled values)
  • DNP 3.0 via Ethernet
  • DNP 3.0
  • Profibus DP
  • MODBUS RTU
  • SPABUS
  • LON (on request)
transformer-monitor
transformer-monitor

All necessary functions in a single device

The functional scope of our transformer monitor is unique. The control of 3-winding transformers, of phase-shifting transformers, of transformer banks and of compensation reactors as well as transformer monitoring is all possible with only one device and one firmware.

Parallel operation with up to 15 transformers

The REG-D® allows parallel operation of up to 15 transformers. The parallel program Master-Follower as well as various programs for circuit reactive current minimization (with and without communication between the controllers) are available. The ParaGramer serves as an aid for the automatic recognition of parallel circuits and for the visualization of the switching states. The ParaGramer maps the switching situation of the individual transformers in single-phase representation and enables automatic detection of parallel operation by evaluating the switch positions.

transformer-monitor

AETooblox
The perfect supplement to the REG-D®

The AEToolbox works on a project basis and impresses with its range of functions and the versatility that the program offers. Using the software, the parameters of connected products can be adjusted and administered and the continuously recorded data (logbook entries and recorder data) downloaded, visualised and saved.

Auxiliary components

Accessories for our voltage regulators

News from the Productgroup

REGSys® – News

Product innovation

Product discontinuation: Profibus-DP in the types B01 & B02 as of 15.05.2024

3. June 2024

Profibus-DP in the types B01 & B02 is currently scheduled for product discontinuation.[…]

Read more

General Knowledge

REGSys® Parallel Regulation of Transformers with Tap-Changers

8. January 2024

The regulation of transformers with tap changers is an essential subject within the field of power supply and distribution. Today these tasks are accomplished electronically with high regulation quality.[…]

Read more

Product innovation

Product discontinuation: Protocol-Interface REG-PE, as of 01.10.2022

28. July 2022

The SCADA card REG-PE (TK860) is currently scheduled for product discontinuation.[…]

Read more

Info letter

Info Letter No. 16: Hot-spot temperature and service life of transformers

7. September 2021

The failure of a transformer not only has major economic consequences for the energy supplier, it can…[…]

Read more

Info letter

Info Letter No. 13: Parallel operation of step transformers

7. September 2021

The rule of thumb that with parallel operation of transformers the ratio of the rated outputs should not…[…]

Read more

Info letter

Info Letter No. 11: Voltage regulation with step transformers in parallel to busbars (Part 3)

7. September 2021

Direct measurement of the circulating current is not possible with the usual measurement…[…]

Read more

Info letter

Info Letter No. 10: Voltage regulation with step transformers parallel to busbars (Part 2)

7. September 2021

The following considerations apply to a symmetrical operation of a three-phase network, so that the…[…]

Read more

Info letter

Info Letter No. 9: Voltage regulation with step transformers in parallel to busbars (Part 1)

7. September 2021

Within a station, the transformers are in close proximity. Therefore, the line impedances between the…[…]

Read more

Info letter

Info Letter No. 7: Load-dependent voltage change

7. September 2021

For the regulation of the voltage ULoad at a predetermined value at the specified load point (e.g. the…[…]

Read more

Info letter

Info Letter No. 4: Summation of Alternating Currents

7. September 2021

For the parallel connection of power sources, the principle of superposition applies, when all resources…[…]

Read more

Special Publication

Regulating the Active and Reactive Power with REGSys®

7. March 2021

he voltage regulator REG-D(A) is normally tasked with controlling voltage on the secondary side of a transformer. The main task here is to achieve the best possible balance between voltage stability and[…]

Read more

Special Publication

The REGSys® Triple-Wound Feature

7. March 2021

Since then, it has become possible to use the feature for other application such as so-called “energetic recovery” or to implement applications requiring a second voltage (U1, U2) and current (I1,[…]

Read more

Special Publication

Safely Regulate the Load Flow

7. March 2021

Phase-shifting transformers or shunt regulators are special power transformers. They allow the active power flow (load flow) in alternating current networks to be controlled. During tapping, the …[…]

Read more

Contact request:



* Mandatory

Your data is being processed